J Clin Monit Comput - Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation.

Tópicos

{ blood(1257) pressur(1144) flow(957) }
{ perform(1367) use(1326) method(1137) }
{ featur(3375) classif(2383) classifi(1994) }
{ cancer(2502) breast(956) screen(824) }
{ extract(1171) text(1153) clinic(932) }
{ measur(2081) correl(1212) valu(896) }
{ imag(1057) registr(996) error(939) }
{ assess(1506) score(1403) qualiti(1306) }
{ model(3480) simul(1196) paramet(876) }
{ surgeri(1148) surgic(1085) robot(1054) }
{ concept(1167) ontolog(924) domain(897) }
{ ehr(2073) health(1662) electron(1139) }
{ group(2977) signific(1463) compar(1072) }
{ intervent(3218) particip(2042) group(1664) }
{ use(976) code(926) identifi(902) }
{ clinic(1479) use(1117) guidelin(835) }
{ method(1557) propos(1049) approach(1037) }
{ control(1307) perform(991) simul(935) }
{ method(984) reconstruct(947) comput(926) }
{ spatial(1525) area(1432) region(1030) }
{ health(3367) inform(1360) care(1135) }
{ research(1218) medic(880) student(794) }
{ patient(2837) hospit(1953) medic(668) }
{ model(2656) set(1616) predict(1553) }
{ first(2504) two(1366) second(1323) }
{ activ(1138) subject(705) human(624) }
{ use(2086) technolog(871) perceiv(783) }
{ structur(1116) can(940) graph(676) }
{ model(3404) distribut(989) bayesian(671) }
{ sequenc(1873) structur(1644) protein(1328) }
{ imag(2830) propos(1344) filter(1198) }
{ studi(1410) differ(1259) use(1210) }
{ monitor(1329) mobil(1314) devic(1160) }
{ age(1611) year(1155) adult(843) }
{ sampl(1606) size(1419) use(1276) }
{ can(981) present(881) function(850) }
{ high(1669) rate(1365) level(1280) }
{ process(1125) use(805) approach(778) }
{ method(1969) cluster(1462) data(1082) }
{ can(774) often(719) complex(702) }
{ imag(1947) propos(1133) code(1026) }
{ data(1737) use(1416) pattern(1282) }
{ inform(2794) health(2639) internet(1427) }
{ system(1976) rule(880) can(841) }
{ bind(1733) structur(1185) ligand(1036) }
{ method(1219) similar(1157) match(930) }
{ network(2748) neural(1063) input(814) }
{ imag(2675) segment(2577) method(1081) }
{ patient(2315) diseas(1263) diabet(1191) }
{ take(945) account(800) differ(722) }
{ studi(2440) review(1878) systemat(933) }
{ motion(1329) object(1292) video(1091) }
{ treatment(1704) effect(941) patient(846) }
{ framework(1458) process(801) describ(734) }
{ problem(2511) optim(1539) algorithm(950) }
{ error(1145) method(1030) estim(1020) }
{ chang(1828) time(1643) increas(1301) }
{ learn(2355) train(1041) set(1003) }
{ algorithm(1844) comput(1787) effici(935) }
{ data(1714) softwar(1251) tool(1186) }
{ design(1359) user(1324) use(1319) }
{ model(2220) cell(1177) simul(1124) }
{ care(1570) inform(1187) nurs(1089) }
{ general(901) number(790) one(736) }
{ search(2224) databas(1162) retriev(909) }
{ featur(1941) imag(1645) propos(1176) }
{ case(1353) use(1143) diagnosi(1136) }
{ howev(809) still(633) remain(590) }
{ data(3963) clinic(1234) research(1004) }
{ risk(3053) factor(974) diseas(938) }
{ perform(999) metric(946) measur(919) }
{ research(1085) discuss(1038) issu(1018) }
{ system(1050) medic(1026) inform(1018) }
{ import(1318) role(1303) understand(862) }
{ model(2341) predict(2261) use(1141) }
{ visual(1396) interact(850) tool(830) }
{ compound(1573) activ(1297) structur(1058) }
{ studi(1119) effect(1106) posit(819) }
{ record(1888) medic(1808) patient(1693) }
{ state(1844) use(1261) util(961) }
{ data(2317) use(1299) case(1017) }
{ medic(1828) order(1363) alert(1069) }
{ signal(2180) analysi(812) frequenc(800) }
{ cost(1906) reduc(1198) effect(832) }
{ gene(2352) biolog(1181) express(1162) }
{ data(3008) multipl(1320) sourc(1022) }
{ time(1939) patient(1703) rate(768) }
{ patient(1821) servic(1111) care(1106) }
{ analysi(2126) use(1163) compon(1037) }
{ health(1844) social(1437) communiti(874) }
{ use(1733) differ(960) four(931) }
{ drug(1928) target(777) effect(648) }
{ result(1111) use(1088) new(759) }
{ implement(1333) system(1263) develop(1122) }
{ survey(1388) particip(1329) question(1065) }
{ estim(2440) model(1874) function(577) }
{ decis(3086) make(1611) patient(1517) }
{ activ(1452) weight(1219) physic(1104) }
{ method(2212) result(1239) propos(1039) }
{ detect(2391) sensit(1101) algorithm(908) }

Resumo

JECTIVE: There is a need for an automated bedside functional residual capacity (FRC) measurement method that does not require a step change in inspired oxygen fraction. Such a method can be used for patients who require a high inspired oxygen fraction to maintain arterial oxygenation and for patients ventilated using a circle breathing system commonly found in operating rooms, which is not capable of step changes in oxygen. We developed a CO(2) rebreathing method for FRC measurement that is based on the change in partial pressure of end-tidal carbon dioxide and volume of CO(2) eliminated at the end of a partial rebreathing period. This study was designed to assess the accuracy and precision of the proposed FRC measurement system compared to body plethysmography and nitrogen washout FRC.METHODS: Accuracy and precision of measurements were assessed by comparing the CO(2) rebreathing FRC values to the gold standard, body plethysmography FRC, in twenty spontaneously breathing volunteers. The CO(2) rebreathing FRC measurements were then compared to nitrogen washout FRC in twenty intensive care patients whose lungs were mechanically ventilated. For each subject, an average value of CO(2) rebreathing FRC was compared to the average gold standard method. Measurements were accepted for statistical analysis if they had been recorded from periods of stable tidal ventilation, defined as a coefficient of variation of tidal volume of <0.13.RESULTS: Compared to body plethysmography, the accuracy (average error) for the CO(2) rebreathing method during stable ventilation (n?=?8) was 0.03?L and precision (1 standard deviation of the error) was 0.29?L (0.8 ? 7.6% of body plethysmography). During stable mechanical ventilation (n?=?9), the accuracy was -0.02?L and precision was 0.26?L (-1.1 ? 12.6% of nitrogen washout).CONCLUSIONS: The CO(2) rebreathing method for FRC measurement provides acceptable accuracy and precision during stable ventilation compared to the gold standards of body plethysmography and nitrogen washout. The results based on periods of stable ventilation best approximate the performance of the system in the likely areas of application during controlled mechanical ventilation. Further study of the CO(2) rebreathing method is needed to evaluate accuracy in a larger group of controlled mechanical ventilation patients, including patients with respiratory insufficiency and significant lung injury.

Resumo Limpo

jectiv need autom bedsid function residu capac frc measur method requir step chang inspir oxygen fraction method can use patient requir high inspir oxygen fraction maintain arteri oxygen patient ventil use circl breath system common found oper room capabl step chang oxygen develop co rebreath method frc measur base chang partial pressur endtid carbon dioxid volum co elimin end partial rebreath period studi design assess accuraci precis propos frc measur system compar bodi plethysmographi nitrogen washout frcmethod accuraci precis measur assess compar co rebreath frc valu gold standard bodi plethysmographi frc twenti spontan breath volunt co rebreath frc measur compar nitrogen washout frc twenti intens care patient whose lung mechan ventil subject averag valu co rebreath frc compar averag gold standard method measur accept statist analysi record period stabl tidal ventil defin coeffici variat tidal volum result compar bodi plethysmographi accuraci averag error co rebreath method stabl ventil n l precis standard deviat error l bodi plethysmographi stabl mechan ventil n accuraci l precis l nitrogen washoutconclus co rebreath method frc measur provid accept accuraci precis stabl ventil compar gold standard bodi plethysmographi nitrogen washout result base period stabl ventil best approxim perform system like area applic control mechan ventil studi co rebreath method need evalu accuraci larger group control mechan ventil patient includ patient respiratori insuffici signific lung injuri

Resumos Similares

J Clin Monit Comput - Hemodynamic volumetry using transpulmonary ultrasound dilution (TPUD) technology in a neonatal animal model. ( 0,797381650747733 )
Comput Math Methods Med - Simulation of exercise-induced syncope in a heart model with severe aortic valve stenosis. ( 0,794026442305346 )
Comput Math Methods Med - Numerical study for blood flow in pulmonary arteries after repair of tetralogy of Fallot. ( 0,793475532906047 )
J Clin Monit Comput - Continuous minimally invasive peri-operative monitoring of cardiac output by pulmonary capnotracking: comparison with thermodilution and transesophageal echocardiography. ( 0,781047274301465 )
J Clin Monit Comput - Heart sounds analysis via esophageal stethoscope system in beagles. ( 0,776599642171096 )
J Clin Monit Comput - Assessment of the effect of rapid crystalloid infusion on stroke volume variation and pleth variability index after a preoperative fast. ( 0,772007233142033 )
J Clin Monit Comput - Changes in R-Wave amplitude in DII lead is less sensitive than pulse pressure variation to detect changes in stroke volume after fluid challenge in ICU patients postoperatively to cardiac surgery. ( 0,770072279501177 )
J Clin Monit Comput - Transthoracic electrical bioimpedence cardiac output: comparison with multigated equillibrium radionuclide cardiography. ( 0,76801168106135 )
J Clin Monit Comput - Variations in the pre-ejection period induced by deep breathing do not predict the hemodynamic response to early haemorrhage in healthy volunteers. ( 0,766531254513959 )
Med Biol Eng Comput - Assessment of dynamic cerebral autoregulation and cerebral carbon dioxide reactivity during normothermic cardiopulmonary bypass. ( 0,763384214012986 )
J Clin Monit Comput - Non-invasive cardiac output and oxygen delivery measurement in an infant with critical anemia. ( 0,760634789667128 )
J Clin Monit Comput - Decrease in pulmonary artery pressure after administration of thoracic epidural anesthesia in a patient with Marfan syndrome awaiting aortic valve replacement procedure. ( 0,760596435709839 )
J Clin Monit Comput - Pulmonary artery pulsatility is the main cause of cardiogenic oscillations. ( 0,760307342058898 )
J Clin Monit Comput - Noninvasive continuous hemodynamic monitoring. ( 0,760195963438174 )
Med Biol Eng Comput - A coupled flow-acoustic computational study of bruits from a modeled stenosed artery. ( 0,759790742780009 )
Comput Math Methods Med - Mathematical analysis of non-Newtonian blood flow in stenosis narrow arteries. ( 0,759778262543541 )
Med Biol Eng Comput - Characterization of skin dermis microcirculation in flow-mediated dilation using optical sensor with pressurization mechanism. ( 0,759243906946994 )
J Clin Monit Comput - Capability of a new paediatric oesophageal Doppler monitor to detect changes in cardiac output during testing of external pacemakers after cardiac surgery. ( 0,7585955207447 )
J Clin Monit Comput - In-line pressure within a HOTLINE? Fluid Warmer, under various flow conditions. ( 0,755288552885024 )
J Clin Monit Comput - Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial. ( 0,754429250211369 )
Comput Math Methods Med - Plasma volume expansion resulting from intravenous glucose tolerance test. ( 0,754308935428058 )
Med Biol Eng Comput - Arterial reservoir-excess pressure and ventricular work. ( 0,7538285957694 )
Med Biol Eng Comput - Cardiac oxygen supply is compromised during the night in hypertensive patients. ( 0,75112705044999 )
J Clin Monit Comput - Cardiopulmonary interactions and volume status assessment. ( 0,75030649840638 )
J Clin Monit Comput - Assessment of cerebral oxygenation using near infrared spectroscopy during isovolemic hemodilution in pediatric patients. ( 0,750200533310677 )
Med Biol Eng Comput - Determinants of vascular and cardiac baroreflex sensitivity values in a random population sample. ( 0,749506088415617 )
Comput Methods Programs Biomed - Measurements of the left atrium and pulmonary veins for analysis of reverse structural remodeling following cardiac ablation therapy. ( 0,748750575141232 )
J Clin Monit Comput - Fluid responsiveness is about stroke volume, and not pulse pressure Yogi: the power of Doppler fluid management and cardiovascular monitoring. ( 0,747802302437336 )
J Clin Monit Comput - Transesophageal echocardiography and intraoperative phlebotomy during surgical repair of coarctation of aorta in a patient with atrial septal defect, moderately severe mitral regurgitation and severe pulmonary hypertension. ( 0,74747799174846 )
Med Biol Eng Comput - Transesophageal left ventricular electrogram-recording and temporary pacing to improve patient selection for cardiac resynchronization. ( 0,746915417988575 )
J Clin Monit Comput - Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): comparison of two monitoring sites with the thermodilution cardiac output. ( 0,745906253299463 )
J Clin Monit Comput - The relationship between the area of peripherally-derived pressure volume loops and systemic vascular resistance. ( 0,745170884855057 )
J Clin Monit Comput - Comparison of cardiac output determined by bioimpedance and bioreactance methods at rest and during exercise. ( 0,745163958171406 )
Comput Methods Programs Biomed - Validation of subject-specific cardiovascular system models from porcine measurements. ( 0,744811115098447 )
J Clin Monit Comput - Evaluation of mean systemic filling pressure from pulse contour cardiac output and central venous pressure. ( 0,744203673078175 )
J Clin Monit Comput - Arterial line for monitoring SpO2 in patients with ischemic peripheries. ( 0,741884539640144 )
Comput. Biol. Med. - A semi-automated computer tool for the analysis of retinal vessel diameter dynamics. ( 0,74128666759671 )
Med Biol Eng Comput - Computational model for estimating the short- and long-term cardiac response to arteriovenous fistula creation for hemodialysis. ( 0,739234191292368 )
Comput Methods Programs Biomed - In silico study of the haemodynamic effects induced by mechanical ventilation and biventricular pacemaker. ( 0,738949254349689 )
J Clin Monit Comput - Combination of continuous pulse pressure variation monitoring and cardiac filling pressure to predict fluid responsiveness. ( 0,738672547130496 )
Med Biol Eng Comput - The influence of intraluminal thrombus on noninvasive abdominal aortic aneurysm wall distensibility measurement. ( 0,738534380222833 )
J Clin Monit Comput - Thoracic impedance measures tissue characteristics in the vicinity of the electrodes, not intervening lung water: implications for heart failure monitoring. ( 0,735183173689866 )
J Clin Monit Comput - The effect of endotracheal tube cuff pressure change during gynecological laparoscopic surgery on postoperative sore throat: a control study. ( 0,733973117738408 )
Med Biol Eng Comput - Coronary-aortic interaction during ventricular isovolumic contraction. ( 0,733941122112673 )
Comput. Biol. Med. - A general model for continuous noninvasive pulmonary artery pressure estimation. ( 0,733178788739155 )
Comput. Biol. Med. - The hemodynamic alterations induced by the vascular angular deformation in stent-assisted coiling of bifurcation aneurysms. ( 0,731338865810031 )
J Clin Monit Comput - The use of a noninvasive hemoglobin monitor for determining fluid distribution and elimination in pediatric patients undergoing minor surgery. ( 0,730521824614649 )
Med Biol Eng Comput - Model-based correction of the influence of body position on continuous segmental and hand-to-foot bioimpedance measurements. ( 0,728820333014234 )
J Clin Monit Comput - Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers. Part 1: time domain analysis. ( 0,722700436518543 )
Med Biol Eng Comput - Effect of the degree of LAD stenosis on competitive flow and flow field characteristics in LIMA-to-LAD bypass surgery. ( 0,721821823409977 )
Med Biol Eng Comput - Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence. ( 0,718401431246134 )
Comput Math Methods Med - Simulation of the Frank-Starling Law of the Heart. ( 0,718346004762816 )
Comput Math Methods Med - Evaluation of a model-based hemodynamic monitoring method in a porcine study of septic shock. ( 0,718107755906476 )
J Clin Monit Comput - The changes of pulmonary blood flow in non-ventilated lung during one lung ventilation. ( 0,717452496493557 )
Comput Math Methods Med - Transformation of physical DVHs to radiobiologically equivalent ones in hypofractionated radiotherapy analyzing dosimetric and clinical parameters: a practical approach for routine clinical practice in radiation oncology. ( 0,714263594892567 )
Comput. Biol. Med. - Modeling of heart sound morphology and analysis of the morphological variations induced by respiration. ( 0,714202072894871 )
J Clin Monit Comput - Multimodal noninvasive monitoring of soft tissue wound healing. ( 0,712439919542526 )
Int J Med Robot - Is there a role for robotic totally endoscopic coronary artery bypass in HIV positive patients? ( 0,712164869384403 )
J Clin Monit Comput - Cardiac output measured by uncalibrated arterial pressure waveform analysis by recently released software version 3.02 versus thermodilution in septic shock. ( 0,711670835709424 )
Comput. Biol. Med. - Effect of CPAP therapy on daytime cardiovascular regulations in patients with obstructive sleep apnea. ( 0,711459415968584 )
J Clin Monit Comput - The effects of cardiac output and pulmonary arterial hypertension on volumetric capnography derived-variables during normoxia and hypoxia. ( 0,710636969464127 )
Med Biol Eng Comput - Monitoring intracellular, interstitial, and intravascular volume changes during fluid management procedures. ( 0,710432419999038 )
J Med Syst - Mathematical models of real geometrical factors in restricted blood vessels for the analysis of CAD (coronary artery diseases) using Legendre, Boubaker and Bessel polynomials. ( 0,706207295944668 )
Comput Methods Programs Biomed - Mechanical ventilation and thoracic artificial lung assistance during mechanical circulatory support with PUCA pump: in silico study. ( 0,705141867939393 )
Med Biol Eng Comput - Estimation of mean arterial pressure from the oscillometric cuff pressure: comparison of different techniques. ( 0,70339490892795 )
J Clin Monit Comput - A model-based decision support system for critiquing mechanical ventilation treatments. ( 0,703259084316467 )
J Clin Monit Comput - Tako-tsubo cardiomyopathy and microcirculation. ( 0,703231076578384 )
J Clin Monit Comput - Bedside assessment of passive leg raising effects on venous return. ( 0,703222864206143 )
J Clin Monit Comput - Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis. ( 0,702564926749726 )
Comput Math Methods Med - Evaluating the hemodynamical response of a cardiovascular system under support of a continuous flow left ventricular assist device via numerical modeling and simulations. ( 0,701834416500565 )
J Clin Monit Comput - Impact of skin incision on the pleth variability index. ( 0,69857220396459 )
Comput Math Methods Med - A study of mechanical optimization strategy for cardiac resynchronization therapy based on an electromechanical model. ( 0,697674755435623 )
Comput. Biol. Med. - Biomechanical behaviors of curved artery with flexible wall: a numerical study using fluid-structure interaction method. ( 0,695265331447394 )
Comput Methods Programs Biomed - Impact of pulmonary vascular stiffness and vasodilator treatment in pediatric pulmonary hypertension: 21 patient-specific fluid-structure interaction studies. ( 0,695143742847627 )
J Clin Monit Comput - Pulse oximeter plethysmograph variation and its relationship to the arterial waveform in mechanically ventilated children. ( 0,695036487465715 )
J Clin Monit Comput - Reference values for volumetric capnography-derived non-invasive parameters in healthy individuals. ( 0,694838533658775 )
Comput Methods Programs Biomed - A model of perfusion of the healthy human lung. ( 0,694716899175974 )
J Clin Monit Comput - Continuous real time endotracheal tube cuff pressure waveform. ( 0,694572190335602 )
Telemed J E Health - The informative contribution of the virtual medical visit in a new heart failure telemedicine integrated system. ( 0,694371839011239 )
Med Biol Eng Comput - Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO2 sensor. ( 0,694354672622554 )
Med Biol Eng Comput - Effect of respiration on Korotkoff sounds and oscillometric cuff pressure pulses during blood pressure measurement. ( 0,693414696835309 )
J Clin Monit Comput - Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery. ( 0,693066536341729 )
J Clin Monit Comput - Radial-femoral concordance in time and frequency domain-based estimates of systemic arterial respiratory variation. ( 0,691138768169923 )
Comput Math Methods Med - Computational fluid dynamics simulations of contrast agent bolus dispersion in a coronary bifurcation: impact on MRI-based quantification of myocardial perfusion. ( 0,691042211002123 )
J Clin Monit Comput - Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers part 2: frequency domain analysis. ( 0,690099909946321 )
IEEE J Biomed Health Inform - Experimental investigation of the influence of the aortic stiffness on hemodynamics in the ascending aorta. ( 0,689774572641289 )
Comput Math Methods Med - Influence of distal resistance and proximal stiffness on hemodynamics and RV afterload in progression and treatments of pulmonary hypertension: a computational study with validation using animal models. ( 0,689360295046604 )
J Clin Monit Comput - Pulse perfusion value predicts eye opening after sevoflurane anaesthesia: an explorative study. ( 0,688761281879749 )
Comput. Biol. Med. - Numerical investigation of blood flow in three-dimensional porcine left anterior descending artery with various stenoses. ( 0,68841831828273 )
Wiley Interdiscip Rev Syst Biol Med - Integration of cardiovascular regulation by the blood/endothelium cell-free layer. ( 0,687235796084255 )
J Clin Monit Comput - Pleth variability index-directed fluid management in abdominal surgery under combined general and epidural anesthesia. ( 0,686297310377409 )
Med Biol Eng Comput - Mechanical behaviour and rupture of normal and pathological human ascending aortic wall. ( 0,684807295246967 )
J Clin Monit Comput - Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo. ( 0,68443365801429 )
Comput Math Methods Med - Mathematical modelling of cerebral blood circulation and cerebral autoregulation: towards preventing intracranial hemorrhages in preterm newborns. ( 0,683861012701021 )
Med Biol Eng Comput - The effect of aortic wall and aortic leaflet stiffening on coronary hemodynamic: a fluid-structure interaction study. ( 0,683016649733789 )
J Clin Monit Comput - The pulmonary artery catheter. ( 0,682916152544042 )
Comput Methods Programs Biomed - Quantitative analysis of digital subtraction angiography using optical flow method on occlusive cerebrovascular disease. ( 0,682595349772813 )
Health Informatics J - Reliability and concurrent validity of a peripheral pulse oximeter and health-app system for the quantification of heart rate in healthy adults. ( 0,68134523883121 )
Sci Data - Flow-dependent regulation of genome-wide mRNA and microRNA expression in endothelial cells in vivo. ( 0,680737766179548 )
Comput Math Methods Med - Mathematical modeling of radiofrequency ablation for varicose veins. ( 0,679753584689297 )