Int J Comput Assist Radiol Surg - Calibration of cone beam CT using relative attenuation ratio for quantitative assessment of bone density: a small animal study.

Tópicos

{ imag(1057) registr(996) error(939) }
{ method(984) reconstruct(947) comput(926) }
{ analysi(2126) use(1163) compon(1037) }
{ model(2220) cell(1177) simul(1124) }
{ assess(1506) score(1403) qualiti(1306) }
{ method(1219) similar(1157) match(930) }
{ high(1669) rate(1365) level(1280) }
{ error(1145) method(1030) estim(1020) }
{ state(1844) use(1261) util(961) }
{ sampl(1606) size(1419) use(1276) }
{ imag(2830) propos(1344) filter(1198) }
{ algorithm(1844) comput(1787) effici(935) }
{ import(1318) role(1303) understand(862) }
{ activ(1138) subject(705) human(624) }
{ survey(1388) particip(1329) question(1065) }
{ activ(1452) weight(1219) physic(1104) }
{ system(1976) rule(880) can(841) }
{ measur(2081) correl(1212) valu(896) }
{ patient(2315) diseas(1263) diabet(1191) }
{ framework(1458) process(801) describ(734) }
{ clinic(1479) use(1117) guidelin(835) }
{ data(1714) softwar(1251) tool(1186) }
{ general(901) number(790) one(736) }
{ data(3963) clinic(1234) research(1004) }
{ first(2504) two(1366) second(1323) }
{ process(1125) use(805) approach(778) }
{ method(2212) result(1239) propos(1039) }
{ detect(2391) sensit(1101) algorithm(908) }
{ model(3404) distribut(989) bayesian(671) }
{ can(774) often(719) complex(702) }
{ imag(1947) propos(1133) code(1026) }
{ data(1737) use(1416) pattern(1282) }
{ inform(2794) health(2639) internet(1427) }
{ bind(1733) structur(1185) ligand(1036) }
{ sequenc(1873) structur(1644) protein(1328) }
{ featur(3375) classif(2383) classifi(1994) }
{ network(2748) neural(1063) input(814) }
{ imag(2675) segment(2577) method(1081) }
{ take(945) account(800) differ(722) }
{ studi(2440) review(1878) systemat(933) }
{ motion(1329) object(1292) video(1091) }
{ treatment(1704) effect(941) patient(846) }
{ surgeri(1148) surgic(1085) robot(1054) }
{ problem(2511) optim(1539) algorithm(950) }
{ chang(1828) time(1643) increas(1301) }
{ learn(2355) train(1041) set(1003) }
{ concept(1167) ontolog(924) domain(897) }
{ extract(1171) text(1153) clinic(932) }
{ method(1557) propos(1049) approach(1037) }
{ design(1359) user(1324) use(1319) }
{ control(1307) perform(991) simul(935) }
{ care(1570) inform(1187) nurs(1089) }
{ search(2224) databas(1162) retriev(909) }
{ featur(1941) imag(1645) propos(1176) }
{ case(1353) use(1143) diagnosi(1136) }
{ howev(809) still(633) remain(590) }
{ studi(1410) differ(1259) use(1210) }
{ risk(3053) factor(974) diseas(938) }
{ perform(999) metric(946) measur(919) }
{ research(1085) discuss(1038) issu(1018) }
{ system(1050) medic(1026) inform(1018) }
{ model(2341) predict(2261) use(1141) }
{ visual(1396) interact(850) tool(830) }
{ compound(1573) activ(1297) structur(1058) }
{ perform(1367) use(1326) method(1137) }
{ studi(1119) effect(1106) posit(819) }
{ blood(1257) pressur(1144) flow(957) }
{ spatial(1525) area(1432) region(1030) }
{ record(1888) medic(1808) patient(1693) }
{ health(3367) inform(1360) care(1135) }
{ model(3480) simul(1196) paramet(876) }
{ monitor(1329) mobil(1314) devic(1160) }
{ ehr(2073) health(1662) electron(1139) }
{ research(1218) medic(880) student(794) }
{ patient(2837) hospit(1953) medic(668) }
{ model(2656) set(1616) predict(1553) }
{ data(2317) use(1299) case(1017) }
{ age(1611) year(1155) adult(843) }
{ medic(1828) order(1363) alert(1069) }
{ signal(2180) analysi(812) frequenc(800) }
{ cost(1906) reduc(1198) effect(832) }
{ group(2977) signific(1463) compar(1072) }
{ gene(2352) biolog(1181) express(1162) }
{ data(3008) multipl(1320) sourc(1022) }
{ intervent(3218) particip(2042) group(1664) }
{ time(1939) patient(1703) rate(768) }
{ patient(1821) servic(1111) care(1106) }
{ use(2086) technolog(871) perceiv(783) }
{ can(981) present(881) function(850) }
{ health(1844) social(1437) communiti(874) }
{ structur(1116) can(940) graph(676) }
{ cancer(2502) breast(956) screen(824) }
{ use(976) code(926) identifi(902) }
{ use(1733) differ(960) four(931) }
{ drug(1928) target(777) effect(648) }
{ result(1111) use(1088) new(759) }
{ implement(1333) system(1263) develop(1122) }
{ estim(2440) model(1874) function(577) }
{ decis(3086) make(1611) patient(1517) }
{ method(1969) cluster(1462) data(1082) }

Resumo

RPOSE: Cone beam computed tomography (CBCT) has the disadvantage of providing non-quantitative results for bone density determination. The aim of this study is to calibrate CBCT results by using an internal reference (such as muscle) for quantitatively assessing bone density.METHODS: We developed a new method using the relative attenuation ratio between two nearby materials (such as bone and muscle) for systemic error correction in CBCT that depends on the relative object position in the image volume. Phantom calibration was performed to calculate the acquired attenuation ratio in Hounsfield units (HU), comparable to the results from clinical multislice spiral computed tomography (MSCT). In addition, a small animal study with an osteoporotic rat model was evaluated to show the feasibility of this presented method to quantitatively assess bone density using a CBCT system.RESULTS: The phantom study results showed that the calibration process successfully corrected the systemic inaccuracy from CBCT, and the calibrated HU values agreed with the values measured from MSCT. In the small animal study, the quantitative bone densities assessed from the calibrated CBCT results were consistent with the results from MSCT data.CONCLUSION: A practical method to quantitatively estimate attenuation (HU) values for bone tissues from CBCT scans that are comparable to MSCT scans is proposed. The method may improve the quantification ability of CBCT scanning without any additional hardware requirements.

Resumo Limpo

rpose cone beam comput tomographi cbct disadvantag provid nonquantit result bone densiti determin aim studi calibr cbct result use intern refer muscl quantit assess bone densitymethod develop new method use relat attenu ratio two nearbi materi bone muscl system error correct cbct depend relat object posit imag volum phantom calibr perform calcul acquir attenu ratio hounsfield unit hu compar result clinic multislic spiral comput tomographi msct addit small anim studi osteoporot rat model evalu show feasibl present method quantit assess bone densiti use cbct systemresult phantom studi result show calibr process success correct system inaccuraci cbct calibr hu valu agre valu measur msct small anim studi quantit bone densiti assess calibr cbct result consist result msct dataconclus practic method quantit estim attenu hu valu bone tissu cbct scan compar msct scan propos method may improv quantif abil cbct scan without addit hardwar requir

Resumos Similares

Comput Methods Programs Biomed - Statistical shape analysis of clavicular cortical bone with applications to the development of mean and boundary shape models. ( 0,795458738092608 )
Comput. Aided Surg. - Properties of the target registration error for surface matching in neuronavigation. ( 0,720239671057568 )
Int J Comput Assist Radiol Surg - 3D femur model reconstruction from biplane X-ray images: a novel method based on Laplacian surface deformation. ( 0,709923922079927 )
IEEE J Biomed Health Inform - Automated recovery of the center of rotation in optical projection tomography in the presence of scattering. ( 0,704276546221997 )
Comput Methods Programs Biomed - An enhanced method for registration of dental surfaces partially scanned by a 3D dental laser scanning. ( 0,699786865184343 )
Comput. Biol. Med. - Principal direction of inertia for 3D trajectories from patient-specific TMJ movement. ( 0,679099167310267 )
Comput Math Methods Med - Volume-rendering-based interactive 3D measurement for quantitative analysis of 3D medical images. ( 0,67875343968106 )
Int J Comput Assist Radiol Surg - An in vivo subject-specific 3D functional knee joint model using combined MR imaging. ( 0,675787068612201 )
Comput Math Methods Med - 3D analysis of the proximal interphalangeal joint kinematics during flexion. ( 0,667014084226111 )
Int J Comput Assist Radiol Surg - A projected landmark method for reduction of registration error in image-guided surgery systems. ( 0,663862023988123 )
Int J Comput Assist Radiol Surg - Optimized viewing angles for cardiac electrophysiology ablation procedures. ( 0,629425772430324 )
IEEE Trans Vis Comput Graph - D-Snake: Image Registration by As-Similar-As-Possible Template Deformation. ( 0,628518781168856 )
Int J Comput Assist Radiol Surg - Open-source surface mesh-based ultrasound-guided spinal intervention simulator. ( 0,626514398772148 )
Int J Comput Assist Radiol Surg - Three-dimensional histological specimen preparation for accurate imaging and spatial reconstruction of the middle and inner ear. ( 0,625580054098683 )
Med Biol Eng Comput - A hybrid reconstruction algorithm for fluorescence tomography using Kirchhoff approximation and finite element method. ( 0,624624389485909 )
Comput Math Methods Med - Research on calculation of the IOL tilt and decentration based on surface fitting. ( 0,618453516252675 )
Int J Comput Assist Radiol Surg - An electromagnetic Tracker-in-Table configuration for X-ray fluoroscopy and cone-beam CT-guided surgery. ( 0,615696933175142 )
IEEE Trans Image Process - 3-D reconstruction of microtubules from multi-angle total internal reflection fluorescence microscopy using Bayesian framework. ( 0,61541025270453 )
Med Biol Eng Comput - Estimation of the retainer height biomechanical contribution in posterior resin-bonded fixed partial dentures: a structural-thermal coupled finite element analysis. ( 0,613758785993232 )
Methods Inf Med - Lung registration using automatically detected landmarks. ( 0,612041202009888 )
Med Biol Eng Comput - Computation of a finite element-conformal tetrahedral mesh approximation for simulated soft tissue deformation using a deformable surface model. ( 0,611008580302609 )
Comput. Biol. Med. - Comparison of isometric and anatomical graft placement in synthetic ACL reconstructions: a pilot study. ( 0,610709386858791 )
Int J Comput Assist Radiol Surg - Towards ultrasound probe positioning optimization during prostate needle biopsy using pressure feedback. ( 0,610056166861804 )
Comput. Biol. Med. - Elastic image registration using hierarchical spatially based mean shift. ( 0,609598861649695 )
Comput Methods Programs Biomed - Simultaneous attenuation and scatter corrections from the projections in small animal PET imaging. ( 0,603358038864824 )
IEEE Trans Pattern Anal Mach Intell - 2D Affine and Projective Shape Analysis. ( 0,60281503735556 )
IEEE Trans Image Process - Nonrigid registration of 2-D and 3-D dynamic cell nuclei images for improved classification of subcellular particle motion. ( 0,595870775503349 )
Comput. Biol. Med. - Comparison of an analog and digital quantitative and qualitative analysis for the fit of dental copings. ( 0,593677148825354 )
Int J Med Robot - Accuracy study of a robotic system for MRI-guided prostate needle placement. ( 0,593399133059538 )
Int J Med Robot - A study on the theoretical and practical accuracy of conoscopic holography-based surface measurements: toward image registration in minimally invasive surgery. ( 0,592057852109148 )
Int J Comput Assist Radiol Surg - 4D-CT Lung registration using anatomy-based multi-level multi-resolution optical flow analysis and thin-plate splines. ( 0,591889624598666 )
Comput. Biol. Med. - Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging. ( 0,591102612486893 )
Int J Comput Assist Radiol Surg - Validation of automated ultrasound-CT registration of vertebrae. ( 0,590329892617269 )
Med Biol Eng Comput - Joint-specific distance thresholds for patient-specific approximations of articular cartilage modeling in the first ray of the foot. ( 0,589548656948067 )
J Am Med Inform Assoc - Registration of whole immunohistochemical slide images: an efficient way to characterize biomarker colocalization. ( 0,587925063621507 )
Med Biol Eng Comput - Reliability and precision of 3D wireless measurement of scapular kinematics. ( 0,587863694062307 )
Int J Med Robot - Evaluation of a neurosurgical robotic system to make accurate burr holes. ( 0,586998522232066 )
Comput. Aided Surg. - Methods for abdominal respiratory motion tracking. ( 0,585612608700355 )
Med Biol Eng Comput - In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation. ( 0,581226719157236 )
Int J Med Robot - Accuracy of a hexapod parallel robot kinematics based external fixator. ( 0,577243863464659 )
Comput. Biol. Med. - Structured errors in reconstruction methods for Non-Cartesian MR data. ( 0,576633859744854 )
Int J Comput Assist Radiol Surg - Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generator. ( 0,576501573001529 )
Int J Comput Assist Radiol Surg - Design and analysis of a head-mounted parallel kinematic device for skull surgery. ( 0,576151016187251 )
Comput. Aided Surg. - Virtual reconstruction of pelvic tumor defects based on a gender-specific statistical shape model. ( 0,570201446815542 )
IEEE Trans Image Process - Passive Synthetic Aperture Hitchhiker Imaging of Ground Moving Targets - Part 2: Performance Analysis. ( 0,56988323878368 )
Int J Comput Assist Radiol Surg - Target visibility enhancement for C-arm cone beam CT-fluoroscopy-guided hepatic needle placement: implementation and accuracy evaluation. ( 0,569878203573317 )
Int J Comput Assist Radiol Surg - Determining the position of a patient reference from C-Arm views for image guided navigation. ( 0,568762166836951 )
Med Biol Eng Comput - Wear analysis of chamfered elongated acetabular cup liners. ( 0,568064769023863 )
Comput Math Methods Med - Effectiveness of variable-gain Kalman filter based on angle error calculated from acceleration signals in lower limb angle measurement with inertial sensors. ( 0,565785326739169 )
Int J Comput Assist Radiol Surg - Position error reduction in a mechanical tracking linkage for arthroscopic hip surgery. ( 0,564871495502294 )
Med Biol Eng Comput - Compact tracking of surgical instruments through structured markers. ( 0,563710829969289 )
Int J Comput Assist Radiol Surg - Positioning error evaluation of GPU-based 3D ultrasound surgical navigation system for moving targets by using optical tracking system. ( 0,563606769256812 )
J Telemed Telecare - Quality assessment of X-rays interpreted via teleradiology for M?decins Sans Fronti?res. ( 0,562100002649819 )
IEEE Trans Image Process - Nonrigid brain MR image registration using uniform spherical region descriptor. ( 0,561408235522398 )
Comput Math Methods Med - Nonrigid registration of lung CT images based on tissue features. ( 0,560590861216291 )
IEEE Trans Image Process - A split and merge based ellipse detector with self-correcting capability. ( 0,560482598585858 )
Int J Med Robot - Validation of the femoral component placement during hip resurfacing: a comparison between the conventional jig, patient-specific template, and CT-based navigation. ( 0,560260925101929 )
Comput. Biol. Med. - Computer-aided design of the human aortic root. ( 0,559286353148538 )
Int J Comput Assist Radiol Surg - Real-time marker-free patient registration for electromagnetic navigated bronchoscopy: a phantom study. ( 0,557126942442176 )
Int J Comput Assist Radiol Surg - Estimation of motion fields by non-linear registration for local lung motion analysis in 4D CT image data. ( 0,556667457475906 )
Comput. Biol. Med. - Interactive development of a CT-based tissue model for ultrasound simulation. ( 0,554793060574469 )
Int J Comput Assist Radiol Surg - Acetabular orientation: anatomical and functional measurement. ( 0,553900712299074 )
Comput. Aided Surg. - Computer assisted planning and custom-made surgical guide for malunited pronation deformity after first metatarsophalangeal joint arthrodesis in rheumatoid arthritis: a case report. ( 0,553055439264126 )
Comput Methods Programs Biomed - A computer assessment of the effect of hindfoot alignment on mechanical axis deviation. ( 0,552687861079475 )
IEEE J Biomed Health Inform - Volume Preserved Mass-spring Model with Novel Constraints for Soft Tissue Deformation. ( 0,550393100914571 )
Int J Med Robot - Introducing haptic capabilities to a bone-mounted robot for intra-operative surface scanning. ( 0,550347383587545 )
Med Biol Eng Comput - Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices. ( 0,549189767495276 )
Int J Comput Assist Radiol Surg - Real-time tracking of liver motion and deformation using a flexible needle. ( 0,546587259097067 )
Comput. Aided Surg. - Effect of registration mode on neuronavigation precision: an exploration of the role of random error. ( 0,545925683903193 )
Comput. Biol. Med. - Analytical cone-beam SPECT reconstruction algorithm with non-uniform attenuation for general non-circular orbit. ( 0,545500040220399 )
Int J Comput Assist Radiol Surg - Aortic valve prosthesis tracking for transapical aortic valve implantation. ( 0,545497959936851 )
Comput Math Methods Med - Influence of bundle diameter and attachment point on kinematic behavior in double bundle anterior cruciate ligament reconstruction using computational model. ( 0,545266925338621 )
Comput. Biol. Med. - A new method to evaluate the elastic modulus of cortical bone by using a combined computed tomography and finite element approach. ( 0,544534465584611 )
IEEE Trans Pattern Anal Mach Intell - As-Projective-As-Possible Image Stitching with Moving DLT. ( 0,544166056780143 )
Int J Comput Assist Radiol Surg - An error analysis perspective for patient alignment systems. ( 0,54361512646846 )
Comput Math Methods Med - Effect of relative marker movement on the calculation of the foot torsion axis using a combined Cardan angle and helical axis approach. ( 0,543099559756253 )
Comput Math Methods Med - Nonrigid 3D medical image registration and fusion based on deformable models. ( 0,54248655692258 )
IEEE Trans Image Process - Efficient volume reconstruction for parallel-beam computed laminography by filtered backprojection on multi-core clusters. ( 0,54228312360214 )
Int J Med Robot - Comparison of optical and electromagnetic tracking for navigated lateral skull base surgery. ( 0,54169129085894 )
J Biomed Inform - Optimal marker placement in hadrontherapy: intelligent optimization strategies with augmented Lagrangian pattern search. ( 0,541631276199893 )
Med Biol Eng Comput - Three-dimensional reconstruction of cranial defect using active contour model and image registration. ( 0,541511072090335 )
IEEE Trans Image Process - A general fast registration framework by learning deformation-appearance correlation. ( 0,540881533123991 )
Comput Methods Programs Biomed - Validated finite element models of the proximal femur using two-dimensional projected geometry and bone density. ( 0,540743571509195 )
Int J Comput Assist Radiol Surg - New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation. ( 0,540153227027648 )
IEEE Trans Image Process - Fast vanishing-point detection in unstructured environments. ( 0,539836995332566 )
Int J Comput Assist Radiol Surg - A motion constrained cross-wire phantom for tracked 2D ultrasound calibration. ( 0,538362558148989 )
Int J Comput Assist Radiol Surg - Temporal bone borehole accuracy for cochlear implantation influenced by drilling strategy: an in vitro study. ( 0,538177846674022 )
Int J Comput Assist Radiol Surg - Fully automatic segmentation of the femur from 3D-CT images using primitive shape recognition and statistical shape models. ( 0,537223644946794 )
Comput Math Methods Med - Finite element surface registration incorporating curvature, volume preservation, and statistical model information. ( 0,536249533792466 )
J Med Syst - The effect of textile-based inductive coil sensor positions for heart rate monitoring. ( 0,53508863139497 )
Comput Methods Programs Biomed - Performance comparison of accelerometer calibration algorithms based on 3D-ellipsoid fitting methods. ( 0,534720706488518 )
Int J Comput Assist Radiol Surg - Prostate multimodality image registration based on B-splines and quadrature local energy. ( 0,532793734284273 )
IEEE Trans Image Process - Filtering chromatic aberration for wide acceptance angle electrostatic lenses. ( 0,532164657417213 )
Med Biol Eng Comput - Reaction-diffusion modelling for microphysiometry on cellular specimens. ( 0,531979341084807 )
Int J Med Robot - Anatomical evaluation and stress distribution of intact canine femur. ( 0,531775553585693 )
Int J Comput Assist Radiol Surg - A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging. ( 0,530787078684087 )
Int J Comput Assist Radiol Surg - C-arm angle measurement with accelerometer for brachytherapy: an accuracy study. ( 0,530159593138113 )
IEEE J Biomed Health Inform - Surface EMG decomposition based on K-means clustering and convolution kernel compensation. ( 0,529629295204612 )
Comput Math Methods Med - Nonrigid medical image registration based on mesh deformation constraints. ( 0,528952112795991 )
Artif Intell Med - Intensity-based image registration using scatter search. ( 0,528634968472667 )